DynaPro™ Finger Flex

Categories: Hand, DynaPro™ Series

Ideal “static / dynamic” neuro-inhibiting therapy in a resting hand design with a heat moldable flexible insert that “flexes” at the wrist, MCP and PIP joints of the fingers to accommodate spastic episodes of tone and can be heat molded to “flex” into the contracted joint(s) to provide a therapeutic neuro-inhibiting stretch. A movable thumb stall with an elastic pull strap can be set to reverse mild to moderate thumb adduction. The device provides “static / dynamic” therapy to reverse mild to moderate (< 90°adaptive tissue shortening contractures of the wrist and fingers and provides abnormal reflex arc neuro therapy for patients with spasticity.

 

The DynaProÔ Finger Flex is a resting hand design with a thermoplastic insert that is heat molded approximately 15 to 30 degrees “ahead” of comfortable end range stretch at the wrist (i.e., with wrist contracture of 45 degrees, the insert is heat molded to – 30 to -15° degrees). The finger pan should be heat molded to maintain the fingers in optimal extension. When applied, the flexible insert will “flex” into the wrist contracture applying a therapeutic, inhibiting stretch on the shortened tissue at the wrist and the fingers. The gentle tension applied by the correctly heat molded insert will provide abnormal reflex arc therapy to reduce abnormal tone over time as well as lengthening shortened tissue. As wrist extension is improved, the fingers will also open incrementally farther. The device should be modified by heat molding the insert every 6 to 8 weeks to continue contracture reversal (i.e., when the wrist improves from – 45 to -30, the insert must be heat molded to – 15 to neutral to continue the “flex” therapy). By increasing wearing time to three to six hours per use, the Total End Range Time (TERT) of device wear provides long effects stretch and permanent increases in joint range of motion over time. Orthotic treatment should be continued until function is restored to the affected hand.

HCPCS - L3807


FEATURES AND BENEFITS

  • Static/Flex Neuro -Dynamic Therapy
  • Color Coded Straps
  • Resting hand design with flexible finger platform
  • Flexible wrist, MCP and PIP insert minimizes spastic episodes
  • Finger separators included
  • HCPCS - L3807

 

SIZE                              PRODUCT CODE                    WIDTH OF MP JOINTS      LENGTH

Child                      DP WFF-24C (left or right)                  1 3/4" - 2"                            8 1/4"
Youth                     DP WFF-25Y (left or right)                  2" - 2 1/2"                           10 1/4"
Small                      DP WFF-21S (left or right)                  2 1/2" - 3"                           11 1/4"
Medium               DP WFF-22M (left or right)                3" - 3 1/2"                           12 1/4"
Large                     DP WFF-23L (left or right)                  3 1/2" - 4"                           13 1/4"

 